Hot Tap Digital Flowmeter™ – Monitor your compressed air consumption and that when mounting the flow meter under pressure!

Hot-Tap-Digital-Flowmeter-Durch
Rohs-Compliant

What Is The Digital Flowmeter?

EXAIR’s Digital Flowmeter is the easy way to monitor compressed air consumption and waste! The digital display shows the exact amount of compressed air being used downstream. This makes it possible to save thousands of dollars per year in compressed air waste – helping to identify costly leaks or inefficient air products. Many companies install the Digital Flowmeter on each major leg of their air distribution system to constantly monitor and reduce compressed air usage.

What Is The Hot Tap Digital Flowmeter?

The Hot Tap Digital Flow Meter allows installation under pressure. This means that the pipe on which the Hot Tap is installed does not have to be specially insulated and depressurized beforehand. The installation time is the same as for the other standard meters. The probes are passed through two valves. A silencer catches the chips from the drilling process. The flowmeter is available from 2″ to 8″. The digital display shows the exact amount of compressed air used.  This makes it easy to identify costly leaks or inefficient products. No cutting, welding, adjusting or calibrating is required.

The Hot Tap Digital Flow Meter with integrated USB data logger

EXAIR’s Hot Tap Digital Flowmeter™ with integrated data logger allows installation under pressure, eliminating the need for pipe insulation. The award-winning Model 9147 USB Data Logger connects directly to the Digital Flowmeter and is easy to use. Use the included software to configure the data logger to record flow rate. Download the software to configure and record flow rates from once per second to once every 12 hours. Available for flow meters from 2″ to 8″.

Click here to download the latest software for your USB data logger.

If you disconnect the data logger from the flow meter and connect it to a computer, you can export the data directly to Microsoft Excel using the supplied software. The data logger is also available pre-installed on the Digital Flow Meter.

Model USB Data Logger
9147 USB Data Logger for Digital Flowmeter
H9095-DAT-200px-x-200px
  • Easy to install
  • No moving parts
  • Remote totalizing display and data logger available
  • Optional RS-485 serial output communication card available
  • Sensitive even at low flows
  • No calibration or adjustment required
  • Includes all components necessary for installation
  • Models for use on iron pipe from 2″ – 8″ pipe diameter
  • Models for size 2″ to 8″ iron pipe available upon request
  • Models for size 2″ to 6″ copper pipe available upon request
Digital Flowmeter package

Each Digital Flowmeter comes complete with
18 VDC power supply, 3/16″ drill bit, and hole
locating fixture.

Specifications
Accuracy 5% of reading. Add 1% of full scale for air temperature between 40º to 120ºF (4º to 49ºC). Accuracy will be reduced when flow is outside the specified range.
Operating Pressure 30 to 140 PSIG for best accuracy – 200 PSIG max.
Input Power 250 mA at 18 VDC / Power Adapter 120VAC
Wetted Materials Stainless steel, gold, thermal epoxy and Viton (seal)
Ring Material Aluminium
Display Four-digit LED display
Compliance CE and RoHS
Model Pipe Size Range
H9095-DAT 2″ (Schedule 40 iron) 7 – 680 m³/hr
H9096-DAT 2″ – 1/2″ (Schedule 40 iron) 8 – 850 m³/hr
H9097-DAT 3″ (Schedule 40 iron) 20 – 2039 m³/hr
H9098-DAT 4″ (Schedule 40 iron) 34 – 3398 m³/hr
H90100-DAT 6″ (Schedule 40 iron) 85 – 8495 m³/hr
H90101-DAT 8″ (Schedule 40 iron) 169 – 10194 m³/hr
H9095CU-DAT 2″ (Copper) 5 – 595 m³/hr
H9096CU-DAT 2″- 1/2″ (Copper) 8 – 850 m³/hr
H9097CU-DAT 3″ (Copper) 12 – 1189 m³/hr
H9098CU-DAT 4″ (Copper) 25 – 2548 m³/hr
H90100CU-DAT 6″ (Copper) 85 – 8495 m³/hr
hottapdfmdim-400px-x-400px
A
Series Pipe Size in mm
H9095-DAT 2″ (Schedule 40 iron) 6.43 163
H9096-DAT 2-1/2″ (Schedule 40 iron) 7.20 183
H9097-DAT 3″ (Schedule 40 iron) 7.82 199
H9098-DAT 4″ (Schedule 40 iron) 8.82 224
H90100-DAT 6″ (Schedule 40 iron) 10.95 278
H90101-DAT 8″ (Schedule 40 iron) 12.95 329
hottapdfmdim-400px-x-400px
A
Series Pipe Size in mm
H9095CU-DAT 2″ (Copper) 6.18 157
H9096CU-DAT 2″ – 1/2″ (Copper) 6.95 177
H9097CU-DAT 3″ (Copper) 7.45 189
H9098CU-DAT 4″ (Copper) 8.45 215
H90100CU-DAT 6″ (Copper) 10.45 265